Skip to Content
Category

Pressure switches, measuring instruments and flow monitors

Pressure switch Series 901.6

Pressure switch Series 901.6

Change-over contact; Connection Brass; Diaphragm NBR; Setting scale; 250VAC/6A; 24VDC/2A; Male thread 1/4"; Application: Air, Water, Neutral oils; Protection class See Protection cap (Max. IP65)

Grundversion
Connection Hysteresis range Overpressure protection Range of adjustment Type Sequence
1/4" 3 mbar 0,5 bar 5...20 mbar 901.61 32650002
1/4" 5 mbar 0,5 bar 10...50 mbar 901.62 32650003
1/4" 10 mbar 1 bar 25...100 mbar 901.63 32650004
1/4" 20 mbar 1 bar 50...250 mbar 901.64 32650005
1/4" 150 mbar 10 bar 250...1000 mbar 901.66 32650006
1/4" 500 mbar 10 bar 1000...3000 mbar 901.68 32650007
Pressure switch Series 901.6-EX

Pressure switch Series 901.6-EX

ATEX II 1/2G Ex ia IIB T4 Ga/Gb, II 2G Ex ia IIC T4 Gb, II 2D EX ia IIIB T135°C Db; Change-over contact; Diaphragm NBR; Setting scale; 24VDC/100mA; Male thread 1/4"; Application: Air, Water, Neutral oils

Druckschalter Serie 901.6-EX
Grundversion
Connection Hysteresis range Overpressure protection Range of adjustment Design Type Sequence
1/4" 5 mbar 0,5 bar 10...50 mbar ATEX 901.62-111L6-EX 32660001
1/4" 20 mbar 1 bar 50...250 mbar ATEX 901.64-111L6-EX 32660002
1/4" 150 mbar 10 bar 250...1000 mbar ATEX 901.66-111L6-EX 32660003
1/4" 500 mbar 10 bar 1000...3000 mbar ATEX 901.68-111L6-EX 32660004
1/4" 50 mbar 1 bar 100...500 mbar ATEX 901.65-111L6-EX 32660005
Pressure switch Series 901.9

Pressure switch Series 901.9

Change-over contact; Diaphragm NBR; Setting scale; 250VAC/6A; 24VDC/2A; Male thread 1/4"; Application: Air, Water, Neutral oils; Protection class See Protection cap (Max. IP65)

Grundversion
Connection Hysteresis range Overpressure protection Range of adjustment Type Sequence
1/4" 0,5-2 bar 25 bar 1...6 bar 901.91 32670000
1/4" 0,5-2 bar 25 bar 4...9 bar 901.92 32670001
Pressure switch Series 901.9-EX

Pressure switch Series 901.9-EX

ATEX II 1/2G Ex ia IIB T4 Ga/Gb, II 2G Ex ia IIC T4 Gb, II 2D EX ia IIIB T135°C Db; Change-over contact; Diaphragm NBR; Setting scale; 24VDC/100mA; Male thread 1/4"; Application: Air, Water, Neutral oils

Druckschalter Serie 901.9-EX
Grundversion
Connection Hysteresis range Overpressure protection Range of adjustment Design Type Sequence
1/4" 0,5-2 bar 25 bar 1...6 bar ATEX 901.91-111L6-EX 32680000
1/4" 0,5-2 bar 25 bar 4...9 bar ATEX 901.92-111L6-EX 32680001
Pressure switch Series PDS

Pressure switch Series PDS

Change-over contact; Diaphragm NBR; 250VAC/6A, 24VDC/3A; Female thread 1/4"; Application: Air, Water, Hydraulic oil; Protection class IP65; Connector size 32mm

Grundversion
Connection type Hysteresis range Overpressure protection Range of adjustment Type Sequence
Female thread 0,11...0,3 bar 60 bar 0,2...2 bar PDS-1-002-M-2-1 32690000
Female thread 0,13...0,9 bar 60 bar 0,5...8 bar PDS-1-008-M-2-1 32690001
Female thread 0,15...1,7 bar 60 bar 1...16 bar PDS-1-016-M-2-1 32690002
Pressure switch Series HDS

Pressure switch Series HDS

Change-over contact; Piston seal NBR; 250VAC/6A, 24VDC/4A; Swivel male thread 1/4"; Application: Air, Water, Hydraulic oil; Protection class IP65; Connector size 32mm

Grundversion
Connection type Hysteresis range Overpressure protection Range of adjustment Type Sequence
Swivel male thread 5,5...13 bar 350 bar 10...80 bar HDS-1-080-K-7-1 32700000
Swivel male thread 5,5...17 bar 350 bar 10...120 bar HDS-1-120-K-7-1 32700001