Skip to Content
Search
Your Cart
Loading...
Categories
Loading...
Home Search 0 Wishlist
Category

Other materiales - P02

RCA3D1-300-230/50
Pilot valve 1/8"; 230V50Hz; For filter diaphragm valve Goyen
C001-22-HA-01
Coil Type C001; Connector size 22mm; Voltage 230V/50-60Hz; For humid area; Incl. Fastening nut And 2 O-rings
MH-310-501
3/2-way solenoid valve ; Pressure range 2...10bar;Connection: 1/8"; Connector size 22mm; Actuation Electric/Internal control air; Flow rate 650Nl/min
C001-24-UL
Coil Type C001; Approval CSA/UL;Connector size 22mm; Voltage 120V/50Hz; Classification of insulation H
517.2002
5/2-way solenoid valve, connection: 1/8" actuation: electric/spring, operating pressure: 1,5-8bar incl. coil 24VDC and plug, IP65
C001-31-CV100-1
Connector; With moulded PVC-cable 10 Meter; Connector size 16mm; Voltage 230VAC/DC
MD510301-24VDC
5/2-way valve; Pilot-operated; Pressure range 3...10bar; Actuation Electrical/internal control air; Connector size 16mm; Connection M5; Flow rate 290Nl/min
NM52V1P-PR
5/2-way valve; According to NAMUR; Actuation Pneumatic/internal air; Connection 1/4"; Control port 1/8"; Nominal diameter 8mm; Pressure range 2,5-10bar; Flow rate 1080Nl/min
C001-31-CV50-6
Connector; With moulded PVC-cable 5 Meter; Connector size 16mm; Voltage 250VAC/DC
90000064
Throttle-Intermediate plate; Both sides; Nominal diameter 8mm; For 5/2-way solenoid valve - NAMUR type
C001-31-LVCV20-2-01
Connector; Connector with integrated LED, VDR and PVC-cable (2 m); Red LED; Connector size 16mm; Voltage 24VAC/DC
NM32W1S-SR
3/2-way valve; According to NAMUR; Pilot-operated; Actuation Electrical/spring; Standard coil C001; Connector size 22mm; Connection 1/4"; Nominal diameter 8mm; Function NC; Pressure range 2,5-10bar; Flow rate 1080Nl/min
C001-31-LVCV30-2-01
Connector; With integrated LED, VDR and PVC-cable (3 m); Connector size 16mm; Voltage 24VAC/DC; Dimensions 35,5mmx15,5mm, H=25mm
MNC-310-701-TT-EXD
3/2-way valve; According to NAMUR; Pilot-operated; Actuation Electrical/internal control air; Type of coil MH52 Ex d; Connection G 1/4"; Function NC; Body Aluminium; Low temperature design; Temperature range -50...+50°C; Pressure range 2-10bar; Flow rate 1250Nl/min; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
C002-31-CV430-6-01
Connector; PVC-Cable 430mm; Connector size 22mm; Voltage 250VAC/DC; 3x0,75mm2; Stripping 30mm; With wire end ferrules
MNC-510-701-TT-EXD
5/2-way valve; According to NAMUR; Pilot-operated; Actuation Electrical/internal control air; Type of coil MH52 Ex d; Connection G 1/4"; Function NC; Body Aluminium; Low temperature design; Temperature range -50...+50°C; Pressure range 2...10bar; Flow rate 1250Nl/min; Without Pilot valve; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
C002-31-LV-2-01
Connector; With integrated LED-yellow and VDR; Connector size 22mm; With M12 connection; Voltage 24VAC/DC
C002-31-LVCV30-2
Connector; With integrated LED-yellow, VDR and PVC-cable (3 m); Connector size 22mm; Voltage 24VAC/DC
K32W1S618-1-F-D-A-A
3/2-way solenoid valve, connection: 1/8" nominal size: 6 mm, actuation: electr./spring CS-110V/50-60Hz, with device socket
PS106-18-MS03
3/2-way valve; Pilot-operated; Actuation Electrical/spring; Standard coil C001; Connector size 22mm; Connection 1/8"; Nominal diameter 6mm; Function NC; Pressure range 3,2-10bar; Flow rate 650Nl/min; Voltage 24VDC; With connector