MH-541-701-MA22-24VDC-C002-31-6
MH-541-701
5/4-Directional valve; Pressure range 2...10bar; Actuation Electric/electrical; Coil type MA22; Plug width 22mm; Connection 1/4"; Flow rate 1250Nl/min
MA22-24VDC
Solenoid coil; Plug width 22mm; Tension 24VDC
C002-31-6
Cable plug; Plug width 22mm; Standard; Tension 0-250VAC/DC
PS125818CML03
3/2-way solenoid valve unit; 8-fold; connection: 1/8"; nominal diameter: 1,2 mm; actuation: electric/spring; NC; 24VDC; LED/VDR; fully assembled and tested
PS125-8-18-C-ML03
3/2-way solenoid valve unit; 8-fold; connection: 1/8"; nominal diameter: 1,2 mm; actuation: electric/spring; NC; 24VDC; LED/VDR; fully assembled and tested
VL15210001M
2/2-way filter diaphragm valve; NC; actuation electrical/internal control air; application: cleaning of filter systems; connector size 32 mm; connection screw fitting for tube 11/2"; nominal diameter 44mm; pressure range 0,5...7,5bar; number of diaphragms 2; voltage 24VDC
CGS-3331-316-NE2-HT-ST-XN-D024
5/2-way valve; according to NAMUR; pilot-operated; actuation electrical/spring; connection 1/4"NPT; pressure range 1,8-10,3bar; voltage 24VDC; ATEX
MNH 350 701 TT EX E MB
3/2-way valve and 5/2-way valve; according to NAMUR; pilot-operated; actuation electrical/internal control air; standard coil MA52 EEx e mb; connection G 1/4"; function NC; body Aluminium; low temperature equipment; temperature range -40...+50°C; pressure range 2-10bar; flow rate 1250Nl/min; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
PS128-14N-C
3/2-way valve series PS128; according to NAMUR; pilot-operated; actuation electrical/internal control air; body Aluminium; temperature range -10...+50°C; standard coil MA22; connector size 22mm; connection 1/4"NPT; function NC; pressure range 2-10bar; flow rate 1250Nl/min
PS128-14N-C-01
3/2-way valve; according to NAMUR; series PS128; pilot-operated; actuation electrical/internal control air; standard coil MA52 EEx e mb; connection 1/4"NPT; function NC; body Aluminium; temperature range -10...+50°C; pressure range 2-10bar; flow rate 1250Nl/min; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
PS128-14-C-01
3/2-way valve series PS128; according to NAMUR; pilot-operated; actuation electrical/internal control air; standard coil MA22 EEX M; connection G 1/4"; function NC; body Aluminium; temperature range -10...+50°C; pressure range 2-10bar; flow rate 1250Nl/min; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
PS128-14-C-02
3/2-way valve series PS128; according to NAMUR; pilot-operated; actuation electrical/internal control air; standard coil MA52 EEx e mb; connection G 1/4"; function NC; body Aluminium; low temperature equipment; temperature range -40...+50°C; pressure range 2-10bar; flow rate 1250Nl/min; ATEX Ex II 2G Ex h IIC T6 Gb / Ex II 2D Ex h IIIC T80°C Db
PS157-8-1446-BB-BD-VM-MV-D2H
PS157 valve island; 8-fold; 3x 5/2-way valve electrical/electrical; 2x double 3/2-way valve electrical/spring NC; 2x 5/2-way valve electrical/spring; 2 x free places; flow rate 500 Nl/min; voltage 24VDC; pressure range 3...7bar; pressure connection 1/4"; working ports: 6mm; electrical connection SUB-D-25; protection class IP65
352ME-03.070.3
5/2-way valve; according to ISO 5599/1; pilot-operated; pressure range 2,3...10bar; actuation electrical/internal control air; size ISO3; nominal diameter 13mm; flow rate 4600Nl/min
PS157-4-1446-MM-MM-D2H-03
PS157 valve island; 4-fold; 4x 5/2-way valve electrical/spring; NC; flow rate 500 Nl/min; voltage 24VDC; pressure range 3...7bar; pressure connection 1/4"; working ports: 6mm; electrical connection SUB-D-25; protection class IP65
PS157-6-1446-MM-MM-MV-D2H-03
valve island; 5x5/2-way valve electrical/spring; 1xvacant space; flow rate 500 Nl/min; voltage 24VDC; pressure range 3...7bar; pressure connection 1/4"; electrical connection SUB-D-25; protection class IP65
XNM32W1S6M4-NPT
3/2-way valve; according to NAMUR; pilot-operated; actuation electrical/spring; standard coil XPC; connection 1/4"NPT; nominal diameter 8mm; pressure range 2,5-10bar; flow rate 1080Nl/min; ATEX II 2GD
XPC02400
coil type XPC; ATEXII 2GD Ex d; voltage 24VDC; body Polyamide glass fibre reinforced for high temperatures
PS157-1446-DD-DM-D2V-03
PS157 valve island; 4-fold; 3x Double 3/2-way valve electrical/spring; 1x 5/2-way valve electrical/spring; NC; flow rate 500 Nl/min; voltage 24VDC; pressure range 3...7bar; pressure connection 1/4"; working ports: 6mm; electrical connection SUB-D-25; protection class IP65
108-030-0003
coil; connector size 22mm; voltage 220V/50Hz, 4,8W; Ex mb, Ex tb
NM52W1S-SR-C001-03-C002-31-LV-2
NM52W1S-SR
5/2-way valve; according to NAMUR; pilot-operated; actuation electrical/spring; standard coil C001; connector size 22mm; connection 1/4"; nominal diameter 8mm; pressure range 2,5-10bar; flow rate 1080Nl/min
C001-03
coil type C001; connector size 22mm; voltage 24VDC / 48V/50-60Hz
C002-31-LV-2
connector; connector size 22mm; with integrated LED-yellow and VDR; voltage 24VAC/DC
EWJ-RK-24V
Reset cable; valve island series PS157; multipol